HVU Ubbelohde Viscometers

The Herzog HVU is an automatic Ubbelohde viscometer that uses standard Ubbelohde capillary tubes and a highly stable temperature control system. It is suitable for laboratories that require accurate test results in accordance with ASTM and ISO standards. 

The instrument can test up to 2 samples at the same time using Ubbelohde capillary tubes. Users can select either a Near-Infrared (NIR) liquid level detection system or a Thermal NTC detection system based on the type of sample. These systems accurately detect liquid flow and measure flow time for viscosity calculation. 

The HVU Series is available in 2 models: 

HVU 481: Temperature range from 20 to 150°C. Suitable for viscosity testing of oils and lubricants at medium to high temperatures. 

HVU 482: Temperature range from -40 to 100°C. Suitable for aviation fuels and other samples that require low-temperature testing. 

The temperature control system provides stability of ±0.01°C. This helps samples reach temperature balance quickly and keeps the test conditions stable. The instrument also includes an automatic capillary cleaning system with Kalrez™ seals. These seals are resistant to strong solvents such as toluene and acetone. 

A complete test cycle, including automatic cleaning, takes approximately 30–40 minutes. 

Test results can be displayed on the instrument screen and sent to a printer or LIMS. Users can easily store, check, and review sample information, capillary tube information, test parameters, and previous test results. 

ประสบการณ์กว่า 47 ปี ที่ 200+ โรงงานไทยไว้วางใจ

HVU Ubbelohde Viscometers

Operating System 

Item  Details 
Bath Temperature Stability  Bath temperature stability of ±0.01°C or ±0.02°F 
Bath Temperature Control  Proportional heating control with high-speed bath liquid circulation. Uses jacketed capillary tubes and pressure-based sample stirring. 
Sample Induction  Samples are filled using a syringe. The HVU 481 can be upgraded for use with a 48-position or 96-position automatic sample changer. 
Meniscus Detection/Timing: Near-Infrared (NIR)  High-accuracy Near-Infrared liquid level detection and timing system. Suitable for clean samples, black samples, samples containing water, and samples with electrical conductivity. 
Meniscus Detection/Timing: Thermal NTC  Suitable for samples with low to high viscosity, including cloudy or opaque samples. 
Auto Cleaning  The automatic cleaning system supports up to 2 solvents. Users can set the number of cleaning cycles. The system uses a minimum of 40 mL of solvent. Solvent is filled and drained by gravity without an external vacuum pump. The system also checks whether enough solvent is available for cleaning. Kalrez™ seals support many types of solvents, including acetone. Viton seals are not used. 
Diagnostics & Calibration  Displays and controls the mechanical and electrical system status in real time. The system can be accessed directly from the instrument or through an optional computer network. 

Basic System Requirements 

Item  Details 
Electrical  230 VAC, 50/60 Hz, 1,200 W. A 110 VAC power supply can be used with a transformer. 
Cooling Water  Standard tap water can be used for tests at temperatures from 25 to 60°C. An external circulation cooler is required for tests at temperatures as low as -40°C. 
Solvents  Uses an external solvent supply and supports up to 2 types of solvents. 

Dimensions and Weight

Model  Dimensions  Weight 
HVU 481  350 × 515 × 900 mm  88 kg 
HVU 482  350 × 515 × 900 mm  88 kg 

Accessories

Accessory  Details  Product Code 
Circulation Cooler with Cooler Isolating Valve Adapter  Supports temperatures down to -20°C  08301-000-00 
Circulation Cooler with Cooler Isolating Valve Adapter  Supports temperatures down to -40°C  08284-000-00 
Cooler Isolating Valve  Prevents the bath from being cooled when a temperature above 40°C is selected  101-173 
NTC Detection Capillary Adapter  Capillary tube adapter for the NTC detection system of the HVU 482  108-332 
Waste Level Sensor  Detects the waste level inside the waste container  638-031 

D445, D446, DIN 51562, IP 71, ISO 3104, ISO 3105, GOST 33, DEF STAN 91-091

HVU481, HVU482

Operating System 

Item  Details 
Bath Temperature Stability  Bath temperature stability of ±0.01°C or ±0.02°F 
Bath Temperature Control  Proportional heating control with high-speed bath liquid circulation. Uses jacketed capillary tubes and pressure-based sample stirring. 
Sample Induction  Samples are filled using a syringe. The HVU 481 can be upgraded for use with a 48-position or 96-position automatic sample changer. 
Meniscus Detection/Timing: Near-Infrared (NIR)  High-accuracy Near-Infrared liquid level detection and timing system. Suitable for clean samples, black samples, samples containing water, and samples with electrical conductivity. 
Meniscus Detection/Timing: Thermal NTC  Suitable for samples with low to high viscosity, including cloudy or opaque samples. 
Auto Cleaning  The automatic cleaning system supports up to 2 solvents. Users can set the number of cleaning cycles. The system uses a minimum of 40 mL of solvent. Solvent is filled and drained by gravity without an external vacuum pump. The system also checks whether enough solvent is available for cleaning. Kalrez™ seals support many types of solvents, including acetone. Viton seals are not used. 
Diagnostics & Calibration  Displays and controls the mechanical and electrical system status in real time. The system can be accessed directly from the instrument or through an optional computer network. 

Basic System Requirements 

Item  Details 
Electrical  230 VAC, 50/60 Hz, 1,200 W. A 110 VAC power supply can be used with a transformer. 
Cooling Water  Standard tap water can be used for tests at temperatures from 25 to 60°C. An external circulation cooler is required for tests at temperatures as low as -40°C. 
Solvents  Uses an external solvent supply and supports up to 2 types of solvents. 

Dimensions and Weight

Model  Dimensions  Weight 
HVU 481  350 × 515 × 900 mm  88 kg 
HVU 482  350 × 515 × 900 mm  88 kg 

Accessories

Accessory  Details  Product Code 
Circulation Cooler with Cooler Isolating Valve Adapter  Supports temperatures down to -20°C  08301-000-00 
Circulation Cooler with Cooler Isolating Valve Adapter  Supports temperatures down to -40°C  08284-000-00 
Cooler Isolating Valve  Prevents the bath from being cooled when a temperature above 40°C is selected  101-173 
NTC Detection Capillary Adapter  Capillary tube adapter for the NTC detection system of the HVU 482  108-332 
Waste Level Sensor  Detects the waste level inside the waste container  638-031 

D445, D446, DIN 51562, IP 71, ISO 3104, ISO 3105, GOST 33, DEF STAN 91-091

HVU481, HVU482