Asphalt ViscoPro 2000 Viscometer
The Asphalt-ViscoPro 2000 viscometer works with high-quality in-line and in-tank sensors from Cambridge Viscosity. It is easy to set up and control, with a clear display showing viscosity, temperature, and temperature-compensated viscosity (TCV). Density readings are available as an optional feature.
The instrument offers 13 factory-set standard measurement ranges covering 0.2–20,000 cP. These options allow users to select a suitable range for their application and improve measurement accuracy.
https://chemihouse.com/wp-content/uploads/2026/10/ViscoPro-2000-Brochure.pdf
Asphalt ViscoPro 2000 Viscometer
-
Specification
-
Standard
-
Model
- Power Input: 100–240 VAC, 24 VDC; power consumption: 12 W
- Outputs and Communication: 4–20 mA; one RS232 port as standard / optional RS485; one 5V-TTL alarm output; and one on-off port for alarm or control
- Accuracy: 1.0% of full scale, with results correlated to ASTM D445. Accuracy is ±5% of full scale for the 500–10,000 and 1,000–20,000 cP ranges.
- Repeatability: 0.8% (ASTM D7483)
- Measurement Ranges: Covering 0.2–20,000 cP, with selectable ranges of 0.2–2, 0.25–5, 0.5–10, 1–20, 2.5–50, 5–100, 10–200, 25–500, 50–1,000, 100–2,000, 250–5,000, 500–10,000, and 1,000–20,000 cP
- Wetted Components: Standard 316L/430 stainless steel, with optional Hastelloy, silicon coating, and sanitary components
- Maximum Temperature: 190°C for the sensor; 60°C for the display electronics
- Maximum Pressure: 1,000 psi (70.3 bar), with an optional version rated for 2,200 psi (151 bar)
- Temperature Sensor: PT100
- Certifications: FM, CE, ATEX, NEMA 4, and IP66
- ASTM D7483
- ASTM D445
-
Specification
-
Standard
-
Model
- Power Input: 100–240 VAC, 24 VDC; power consumption: 12 W
- Outputs and Communication: 4–20 mA; one RS232 port as standard / optional RS485; one 5V-TTL alarm output; and one on-off port for alarm or control
- Accuracy: 1.0% of full scale, with results correlated to ASTM D445. Accuracy is ±5% of full scale for the 500–10,000 and 1,000–20,000 cP ranges.
- Repeatability: 0.8% (ASTM D7483)
- Measurement Ranges: Covering 0.2–20,000 cP, with selectable ranges of 0.2–2, 0.25–5, 0.5–10, 1–20, 2.5–50, 5–100, 10–200, 25–500, 50–1,000, 100–2,000, 250–5,000, 500–10,000, and 1,000–20,000 cP
- Wetted Components: Standard 316L/430 stainless steel, with optional Hastelloy, silicon coating, and sanitary components
- Maximum Temperature: 190°C for the sensor; 60°C for the display electronics
- Maximum Pressure: 1,000 psi (70.3 bar), with an optional version rated for 2,200 psi (151 bar)
- Temperature Sensor: PT100
- Certifications: FM, CE, ATEX, NEMA 4, and IP66
- ASTM D7483
- ASTM D445