Freeze, Viscosity & Density for Jet Fuels
Phase Technology’s new JFA-70Xi jet fuel analyzer is the world’s first and only instrument that performs three crucial tests in one unit—freeze point, viscosity and density. The JFA-70Xi features a new, side loaded automatic sample injection port. There’s no longer a need to manually pipette.
The JFA is completely self-cleaning, without the need of solvents. Save time and hassle of cleaning, and avoid any risk of damage to the sample cup.
-
Specification
-
Standard
-
Model
– Approved for jet fuel certification – Fully compliant with D1655, the specification used for release of jet fuel.
– Super fast speed – Three different tests in less than 15 minutes
– Advanced viscosity capability – The only automatic method capable of testing jet fuel viscosity at -40°C in addition to -20°C ; temperature @12 cSt also calculated
– Self cleaning – no solvent required – No pipette required. New vial injection system loads sample automatically.
– No external chiller – Quiet, cool, self-contained thermoelectric cooler; no hazardous liquid bath medium (methanol toxicity)
– Superior precision – Best measured repeatability and reproducibility of any automatic or manual method
D5972 (IP 435), D2386 (IP 16/ISO 3013), DEF STAN 91-091, CGSB 3.23 & 3.24
JFA-70Xi
-
Specification
-
Standard
-
Model
– Approved for jet fuel certification – Fully compliant with D1655, the specification used for release of jet fuel.
– Super fast speed – Three different tests in less than 15 minutes
– Advanced viscosity capability – The only automatic method capable of testing jet fuel viscosity at -40°C in addition to -20°C ; temperature @12 cSt also calculated
– Self cleaning – no solvent required – No pipette required. New vial injection system loads sample automatically.
– No external chiller – Quiet, cool, self-contained thermoelectric cooler; no hazardous liquid bath medium (methanol toxicity)
– Superior precision – Best measured repeatability and reproducibility of any automatic or manual method
D5972 (IP 435), D2386 (IP 16/ISO 3013), DEF STAN 91-091, CGSB 3.23 & 3.24
JFA-70Xi