Atmospheric Distillation: OptiDist 2
OptiDist 2 is the latest Automatic Atmospheric Distillation Analyzer from PAC. Built on the proven success of the OptiDist platform, with more than 5,000 installations worldwide, the new generation focuses on improving test accuracy, enhancing laboratory productivity, and meeting the latest requirements of the petroleum and petrochemical industries.
The OptiDist 2 features an upgraded distillation control system combined with Dual Optimizer Technology. This advanced system continuously monitors both sample temperature and vapor temperature throughout the test. As a result, the instrument can accurately control Initial Boiling Point (IBP) timing according to test method requirements, reducing operator-related variations and minimizing the need for retesting.
One of the key innovations of OptiDist 2 is the redesigned Thermosyphon Condenser cooling system. The patented closed-loop cooling technology operates without moving parts, reducing the number of control components, lowering maintenance requirements, and improving long-term system reliability. In addition, post-test cooling time has been reduced from approximately 15 minutes to only 5 minutes, allowing laboratories to increase sample throughput and overall testing efficiency.
To improve operational safety, OptiDist 2 is equipped with a Safety Door that helps block external UV light and provides additional protection during operation. The instrument also includes a Precondition Verification system that checks testing conditions before analysis begins, helping prevent sample preparation errors and reducing human error that may affect test results.
The instrument is designed with a modular architecture, making diagnostics and troubleshooting faster and easier. This modular design significantly reduces maintenance time and minimizes laboratory downtime, ensuring maximum instrument availability and productivity.
-
Specification
-
Standard
-
Model
Dual Optimizer Technology
Dual Optimizer Technology continuously monitors and controls both sample temperature and vapor temperature in real time. This enables precise heating rate control throughout the distillation process, helping achieve accurate Initial Boiling Point (IBP) measurements and ensuring compliance with test method requirements. The technology improves repeatability, reduces result variation, and minimizes the need for retesting.
Advanced Safety Features
OptiDist 2 is equipped with a comprehensive range of safety features, including a VOC vapor exhaust system, glassware integrity monitoring, automatic fire detection and suppression, and rapid cooling after test completion. The Safety Door also helps block external UV light, providing additional protection and contributing to more stable testing conditions.
User-Friendly Operation
Designed to maximize laboratory efficiency, OptiDist 2 features a large touchscreen display capable of showing both distillation curves and test data simultaneously. Users can easily monitor testing progress in real time. The system supports QR code flask identification to reduce operator errors and includes Precondition Verification to ensure proper test setup before analysis begins. The instrument also supports LTMS integration for streamlined laboratory data management.
Built for Durability and Efficiency
OptiDist 2 is engineered for continuous operation in demanding laboratory environments. Its modular design simplifies diagnostics and maintenance, helping reduce instrument downtime and service interruptions. The Auto Lift Heater Block further improves operator convenience and enhances safety during routine testing procedures.
Thermosyphon Cooling System
The patented Thermosyphon Cooling System uses a closed-loop liquid circulation design without moving parts, providing consistent and reliable condenser cooling performance. This maintenance-friendly design improves system reliability while reducing cooling time after each test to approximately 5 minutes. The result is higher laboratory productivity and the ability to process more samples per day.
D86, D1078, D850, IP195, IP123, DIN51751, NFM07-002, EN ISO3405, JIS K2254, ISO918; D189, D524, D4350, EN ISO 10370, DEF STAN 91-091
OptiDist 2
-
Specification
-
Standard
-
Model
Dual Optimizer Technology
Dual Optimizer Technology continuously monitors and controls both sample temperature and vapor temperature in real time. This enables precise heating rate control throughout the distillation process, helping achieve accurate Initial Boiling Point (IBP) measurements and ensuring compliance with test method requirements. The technology improves repeatability, reduces result variation, and minimizes the need for retesting.
Advanced Safety Features
OptiDist 2 is equipped with a comprehensive range of safety features, including a VOC vapor exhaust system, glassware integrity monitoring, automatic fire detection and suppression, and rapid cooling after test completion. The Safety Door also helps block external UV light, providing additional protection and contributing to more stable testing conditions.
User-Friendly Operation
Designed to maximize laboratory efficiency, OptiDist 2 features a large touchscreen display capable of showing both distillation curves and test data simultaneously. Users can easily monitor testing progress in real time. The system supports QR code flask identification to reduce operator errors and includes Precondition Verification to ensure proper test setup before analysis begins. The instrument also supports LTMS integration for streamlined laboratory data management.
Built for Durability and Efficiency
OptiDist 2 is engineered for continuous operation in demanding laboratory environments. Its modular design simplifies diagnostics and maintenance, helping reduce instrument downtime and service interruptions. The Auto Lift Heater Block further improves operator convenience and enhances safety during routine testing procedures.
Thermosyphon Cooling System
The patented Thermosyphon Cooling System uses a closed-loop liquid circulation design without moving parts, providing consistent and reliable condenser cooling performance. This maintenance-friendly design improves system reliability while reducing cooling time after each test to approximately 5 minutes. The result is higher laboratory productivity and the ability to process more samples per day.
D86, D1078, D850, IP195, IP123, DIN51751, NFM07-002, EN ISO3405, JIS K2254, ISO918; D189, D524, D4350, EN ISO 10370, DEF STAN 91-091
OptiDist 2